Protect the fibre first. Then size the route.
A laser-welding dresspack is organised around the fibre, its minimum bend radius and the tool package. The electrical and gas lines are important, but they must not dictate a bend that the fibre cannot accept.
Start with what the route has to survive.
The process creates the environment; the robot and tool create the geometry. A useful dresspack review connects them before a series or diameter is fixed.
The fibre has a minimum bend radius and limited tolerance for repeated tight bends.
A route that works at the home position can still over-bend during a wrist rotation or tool change.
The fibre connector is sensitive to pull, side load and contamination.
Cable weight and service handling must be carried by the route, not by the connector.
The laser head and process area create a local heat load.
The outer sleeve and any nearby hose need a defined stand-off and inspection zone.
The fibre and lens area need controlled access.
A route that blocks the connector or requires the fibre to be forced aside makes maintenance risky.
What to start with — and what to challenge.
Start here
- Record the fibre's allowed bend radius, torsion limit and connector requirements from the controlled data.
- Keep the fibre in a supported path with strain relief at both ends.
- Separate the fibre from sharp edges, heat sources and heavy service loads.
- Check the laser head, changer and wrist through the full programmed path.
Challenge before release
- Use the electrical cable's bend radius as a substitute for the fibre specification.
- Let the fibre carry the weight of a hose bundle or a service loop.
- Route the fibre through a tight fixed bend to make the outer cover fit.
- Treat a visual inspection as a substitute for the fibre's controlled handling procedure.
The route may need more than one system.

Series 2
Rotary bracket
Wrist-following rotation with a supported fibre path.

Series 5
Telescopic bracket
Compact length storage where the laser head needs clearance.

Series 6
C-flange
Body-following route with an accessible service opening.
What we need to answer usefully.
- Robot brand, exact model, payload, reach and wrist envelope
- Laser head, fibre connector, lens access and tool-change sequence
- Fibre type, outside diameter, minimum bend radius, torsion limit and connector load limit
- Gas, cooling and signal lines with their own bend and service requirements
- Heat sources, sharp edges and the intended inspection zone
- Controlled fibre-handling procedure and who is allowed to disconnect it
Before the kick-off call.
Can the fibre be routed with the electrical cable?
They can share an outer route only when the fibre's bend, torsion, heat and connector requirements are met. The fibre should remain separately supported and protected.
What is the most common routing mistake?
Choosing a compact route at the home position without checking the fibre through wrist rotation, tool change and service access. The drawing must represent the whole motion.
Does a larger conduit always protect the fibre?
No. A larger conduit can add moving mass and may still allow the fibre to move or bend inside it. Support, bend control and strain relief matter as much as diameter.
Start with the robot and the thing that goes wrong.
We will turn the brief into a reference architecture, a list of unknowns and a drawing path.